Phone: (08) 9453 2256
Email: sales@eteh.com.au

Multimeter and Process Calibrator

Based on the trusted Fluke 87 DMM, the 787 adds the ability to measure, source, and simulate dc loop current with 0.05% accuracy and 1 microamp resolution.

General

The Fluke 787 ProcessMeter™ puts a complete troubleshooting solution in the palm of your hand. Get in touch with more information, faster and easier with the newest member of the Fluke 80 Series, the 787 ProcessMeter. The 787 gives you the measurement capabilities you expect from our rugged, reliable DMMs plus the ability to source, simulate, or measure dc current with 1 microamp resolution and accuracy of 0.05%. Put it all together and you have the ideal tool for troubleshooting and calibrating current loop applications. So if you're tired of always tracking down a calibrator, lugging around two tools and switching back and forth, get the single best solution for doubling your power. The 787 ProcessMeter from Fluke.Here's the power the 787 ProcessMeter™ puts into your hands. 

Precision 1000 V, 440 mA digital multimeter 

  • Measure AC and DC volts, AC and DC current, resistance, continuity, and frequency 
  • 0.1% DC voltage accuracy 
  • 0.05% DC current accuracy, 1 ‘A resolution to 30 mA 
  • Simultaneous mA and % of scale readout 
  • True rms AC voltage measurement to 1 kHz 
  • Frequency measurement to 20 kHz 
  • Min/Max/Average/TouchHold/Relative modes 
  • Diode test and continuity beeper 

DC current source/loop calibrator

  • 20 mA current source/simulator 
  • Simultaneous mA and % of scale readout 
  • Manual step (25%, coarse, fine) plus auto step and auto ramp 

Safety Conformance

Meets 1000 volt EN61010-1 CAT III standards.

Request a Quote

Specifications

Fluke 1587 Insulation Multimeters
Specifications
Current measurement Range 0-1 A
  Resolution 1 mA
  Accuracy 0.2% + 2 LSD
  Range 0-30 mA
  Resolution 0.001 mA
  Accuracy 0.05% + 2 LSD
Current sourcing Range 0-20 mA or 4-20 mA
  Resolution 0.05% of span
  Drive Capability 500 Ω @ 24 mA
Frequency   To 19.999 kHz, 0.005% + 1 LSD
Continuity   Beeps for resistance < 100 ohms
Voltage measurement Range 0-1000 V AC or DC
  Resolution 0.1 mV to 1.0 V
  Accuracy 0.1% Rdg + 1 LSD (VDC)
Resistance measurement   To 40 MΩ, 0.2% + 1 LSD
Diode test   2.4 V shows diode voltage drop
Environmental Specifications
Operating temperature   -20°C to 55°C
Storage temperature   -40°C to 60°C
Humidity (without condensation)   95% up to 30°C
    75% up to 40°C
    45% up to 50°C
    35% up to 55°C
Temperature coefficient   0.05 x (specified accuracy) per °C (for temperatures < 18°C or > 28°C)
Safety Specifications
Electrical safety   Designed in accordance with IEC 1010-1, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No. 1010.1-92
Overvoltage category   IEC 1010-1 CAT III
Maximum voltage   1000 V rms